MENU
FEEDBACK

   
ENGLISH   

 الشرق الأوسط‎    

 Deutsch‎   

 خاورمیانه‎  

 Français‎  

Italiano‎  

Português‎  

Español‎  

PCT Connection Series Technical Documentation

Publish Time:2025-10-13 13:47:19 Visit:10

summarized:Quick lever mechanism for <5s installation IP20 protection rating Flame-retardant PA66 housing​

PCT Connection Series Technical Documentation

Product Overview

PCT series connector cross-section
SeriesModelCurrentVoltageWire Range
PCT-412/3/5 Way41A600V0.5-4mm²
PCT-662/3/5 Way66A600V0.5-6mm²
PCT-1088 Port24A400V0.5-2.5mm²

Key Innovations

  • Quick lever mechanism for <5s installation
  • IP20 protection rating
  • Flame-retardant PA66 housing

Electrical Specifications

ParameterPCT-41PCT-66PCT-108
Max Current41A66A24A
Dielectric Strength6kV6kV4kV
Temperature Range-40~+85℃-40~+105℃-40~+85℃
Stripping Length12-14mm12-14mm8-10mm

Material Composition

ComponentMaterialStandard
HousingPA66+30% GFUL94 V-0
ContactsTin-plated brassRoHS 2011/65/EU
SealingEPDM rubberISO 6072

Environmental Resistance

  • UV Resistance: 2000h ASTM G154
  • Corrosion: 96h Salt Spray (ASTM B117)
  • Flammability: IEC 60695-11-10

Application Scenarios

Electrical Installation

  • Building power distribution boards
  • Lighting fixture wiring
  • Appliance control panels

Industrial Systems

  • PLC control cabinets
  • Motor drive systems
  • Renewable energy inverters
Industrial electrical installation

Installation Procedure

  1. Wire Preparation: 12-14mm stripped length
  2. Conductor Insertion: Full insertion with push-in force ≤30N
  3. Lever Operation: 90° rotation until audible click
  4. Visual Check: Confirm conductor engagement through transparent housing

Torque Specifications

ConnectorTorque RangeTest Method
PCT-410.5-0.8 N·mTorque wrench
PCT-660.8-1.2 N·mTension meter
PCT-1080.3-0.5 N·mSpring scale

Maintenance Protocol

IntervalInspection ItemAcceptance Criteria
DailyContact oxidationVisual inspection
MonthlyConnection tightnessTorque recheck
AnnualInsulation resistance≥100MΩ

Replacement Guidelines

  • Seal degradation: Cracks >0.2mm
  • Contact wear: Insertion force >35N
  • Housing damage: Cracks extending to conductors

Compliance Documentation

StandardClauseRequirement
IEC 60947-7-1Section 8Connection reliability
UL 486AClause 5Wire retention
EN 50483Section 6Insulation piercing